Anfrageformular0

Typ 2540 Low-Flow Schaufelradsensor
Standard

The Signet 2540 Paddlewheel flow sensor offers the strength and corrosion resistance of stainless steel for liquid applications with low velocity measurements. Unique internal circuitry eliminates the need for magnets in the process fluid, enabling flow measurement of 0.1 to 6 m/s (0.3 to 20 ft/s) while maintaining the advantages of insertion sensor design. Ultraflon 500C bearings and Tungsten Carbide pin provide exceptional wear resistance.

The Signet 2540 offers field replaceable electronics and transient voltage suppression (TVS) to provide greater immunity to large voltage disturbances (i.e. lightning) sometimes encountered in field wiring. Sensors can be installed in DN40 to DN600 (1½ to 24 in.) pipes using the 1½ inch NPT or ISO 7/1-R 1.5 threaded process connection. The sensors are also offered in a hot-tap configuration with a bleed valve service without process shutdown in pipes up to DN900 (36 in.). Both styles of sensors must be used in full pipes and can be used in low pressure systems.


Durchfluss:
  • *Das Hot Tap-Installationswerkzeug (separat erhältlich)
    198 820 008 (3-1500.663) ist zu verwenden
  • Einbau in Rohrleitungen mit folgenden Größen: DN40 bis DN600, 1,5 bis 24 Zoll
  • Durchfluss-Wertebereich: 0,1 bis 6 m/s
  • Max. Nenndruck: 17 bar bei 100 °C, 250 psi bei 212 °F
    Optional EPDM: 17 bar bei 82 °C, 250 psi bei 180 °F
  • Spannungsquelle: 5 bis 24 VDC, 1,5 mA max.
  • Kompatibilität: 8900, 9900, 9900-1BC, 9950

Technische Daten

MFR
 
Befestigung
 
Rotorzapfen
 
Weitere Masse
 
CAD
 
Code
 
Menge
 
Hinzufügen
3-2540-11.5 in. NPT threadTungsten Carb.Weitere MasseCAD 198840035
3-2540-21.5 in. ISO threadTungsten Carb.Weitere MasseCAD 198840036
3-2540-1S1.5 in. NPT threadStainless SteelWeitere Masse 159001501
3-2540-2S1.5 in. ISO threadStainless SteelWeitere Masse 159001502

Features

Einsatzgebiete:
  • Wasserversorgung
  • Lecküberwachung
  • Beregnung
  • Pumpenschutz
  • Filtersysteme
  • HVAC
  • Nicht geeignet für Gase
  • Kühlsysteme
  • Grundwasseraufbereitung

Standards:
  • CE
  • China RoHS
  • RoHS-konform

Vorteile:
  • Nicht magnetische RF-Erkennung
  • 7,6 m langes Verlängerungskabel

  • Standardmäßige NPT- oder ISO-Prozessverbindungen
  • Heißwasserversion für Installation/Wartung ohne Systemabschaltung
  • Für Rohrgrössen bis DN900 (36'')

  • Austauschbare Elektronik
  • Operating range 0.1 to 6 m/s (0.3 to 20 ft/s)

Dokumente

Bedienungsanleitung
2540_Flow_Sensor_German.pdfPDF1.11 MBDownload
Chinese manual - 2540 Stainless Steel Flow Sensor.pdfPDF1.02 MBDownload
English Manual - 2540 Stainless Steel Flow Sensor.pdfPDF686.77 KBDownload
Italian Manual - 2540 Stainless Steel Flow Sensor.pdfPDF1.32 MBDownload
Portuguese Manual - 2540 Stainless Steel Flow Sensor.pdfPDF1016.71 KBDownload
2540 Rotor Replacement Inst Sheet CEFG.pdfPDF863.8 KBDownload
French Manual - 2540 Stainless Steel Flow Sensor.pdfPDF955.36 KBDownload
Spanish Manual - 2540 Stainless Steel Flow Sensor.pdfPDF959.65 KBDownload

Broschüre
Automation made easy (de).pdfPDF5.29 MBDownload

Datenblatt
Temperature-Pressure Graphs.pdfPDF1.94 MBDownload
Data Sheet - 2540 Stainless Steel High Performance Paddlewheel Flow SensorPDF286.06 KBDownload

Zertifikate
2540 CE Certificate.pdfPDF24.26 KBDownload
Quick Request